Your Location:Home > Services&Products
Site Search
EMIT Electromagnetic Imaging Tubing and Casing Detecting Technology

Technical Indicators and Performance Features 

1.The 2-1/8”instrument body and 18 counter electrode imaging sensors which measure LF- RFEC through tubing, can 

realize: 

  (1)The quantitative measurement of monolayer pipe strings (ETHK). 

  (2)The qualitative measurement of the “total” thickness of multilayered pipe strings.

2.HF- NFEC identifies corrosion on inner/outer wall and provides images accordingly. 

3.Evaluate the quantitative thickness of monolayer and multilayered casing. 

4.Measure the inner diameter and electromagnetic properties of pipe strings. 

5.Carry out operation in any downhole fluids. Field Application

At present, the technology has been successfully applied on 

11 wells with a logging success rate of 100%.