Scope of Application
It is used as acidizing corrosion
inhibiting additive in wells with high temperature (120~190°C), high sulfur
content and none-high sulfur content.
Principles
HYA-06 is a kind of compound corrosion
inhibitor, composed of organic compounds of organic amine, aldehyde and ketone
synthesis, and organic synergistic agent; the cyclic chelates in corrosion
inhibitor can form a complete and dense hydrophobic protective film on the
metal surface, so as to achieve the purpose of corrosion inhibitor.
Technical Indicators (Q/PLS 003-2012)
Item |
Indicator |
||
Appearance |
Uniform liquid |
||
Density g/cm3 (25°C), g/cm3 |
0.80~1.00 |
||
Solubility (in hydrochloric acid) |
Soluble |
||
Corrosion rate,g/m2·h |
90℃ |
20%HCl+1.5%HYA-06 ≤ |
12 |
20%HCl+2%HAc+1.5%HYA-06 ≤ |
15 |
||
130℃ |
20%HCl+2.5%HYA-06 ≤ |
20 |
|
20%HCl+2%HAc+2.5%HYA-06 ≤ |
30 |
Performance Features
It can provide excellent whole and partial corrosion protection for common carbon steel, oil pipe steel, high sulfate-resistant carbon steel and alloy steel etc. Besides, it can easily disperse in acid, reduce the surface tension of reacted acid and has good compatibleness with other additives.
Field Applications
It has been applied for 365 wells/times in
Zhongyuan Oilfield and Puguang Gasfield, providing satisfactory result in
slowing down the damage of high-temperature deep well acidification on oil
pipeline and casing, realizing over 90% of corrosion inhibition rate.